Installation & ADA
Installing your commercial trough sink to compliance
Every SOPHSTONE trough sink is manufactured ADA compliant. Correct carrier installation is what keeps it that way on site — here’s the complete method for PreFab and Designer series.
Watch the install
The full sequence, start to finish
From a bare wall to a mounted, sealed sink — see how carriers, adhesive, and caulk come together.
The method
Mounted in three steps

Step 01
Bolt carriers to studs
Fix primary and secondary carriers to wood studs behind drywall. Primary carriers are the two outermost brackets and carry most of the load.
Primary height: 33 in (34 in rim)
Mount 1 in below top surface
PreFab 29 in · Designer 25¾ in

Step 02
Fix sink to carrier
Set the sink onto the carriers with silicone adhesive. Shim to the intended height and ensure no gap between carrier and sink.
Secondary spacing: max 32 in
Typical 24 in · minimum 18 in

Step 03
Caulk to finished wall
Seal between the sink and finished wall with a continuous silicone bead. Add the optional matching plumbing enclosure to conceal supply and waste lines.
ADA zone below basin
must remain clear
Carrier brackets
Primary vs secondary carriers
Primary carriers
The two outside brackets. They support the majority of the sink and set the mounting height.
- Mount below top surface1 in
- Height for 34 in ADA rim33 in
- PreFab Series29 in
- Designer Series25¾ in
Secondary carriers
Placed under the basin for secondary support along the length of the sink.
- Mount below basin underside¼ in
- Maximum spacing32 in
- Typical spacing24 in
- Minimum spacing18 in
Before you begin
Installation notes
Documents
Download the full set
Need model-specific detail?